Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

곰팡이에 감작된 소아 천식 환자 가정내 환경유해물질 농도와 폐기능의 상관관계

Full metadata record
DC Field Value Language
dc.contributor.author윤원석-
dc.contributor.author임재훈-
dc.contributor.author박상현-
dc.contributor.author이민규-
dc.contributor.author유영-
dc.date.available2021-02-18T02:43:50Z-
dc.date.issued2020-12-
dc.identifier.issn1738-4087-
dc.identifier.urihttps://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/51246-
dc.description.abstractObjectives: Recent data indicate that sensitization to mold contributes to the severity and persistence of asthma. The aim of this study was to investigate relationships between indoor mold concentrations and pulmonary function parameters in asthmatic children with mold sensitization. Methods: Asthmatic subjects who had a positive result in skin-prick testing to more than one mold allergen, such as Alternaria, Aspergillus, or Penicillium, were enrolled. Their pulmonary function and methacholine challenge test results were collected. Measurements of blood eosinophil, serum IgE, and fractional exhaled nitric oxide (FeNO) were taken. Indoor levels of VOC, CO2, PM10 and PM2.5 in each subject’s house were measured. We counted mold and bacteria colonies from the subjects’ house air samples. Results: The mean levels of FEV1, FVC, FEV1/FVC, and FEF25-75 were 82.8±19.7, 87.3±17.9, 85.8±8.3, and 82.3±28.9%, respectively. The mean FeNO level was 19.8±11.2 ppb and the geometric mean (range of one SD) of methacholine PC20 was 3.99 mg/mL (0.67-23.74 mg/mL). The average indoor air pollutant levels were below the recommended levels set by the Ministry of Environment for multiplex buildings. Indoor mold levels showed a significant inverse correlation with methacholine PC20, but not with the baseline pulmonary function parameters. Conclusion: Indoor mold concentrations are a risk factor for increased bronchial hyperresponsiveness among asthmatic children with mold sensitization. Targeted environmental intervention should be considered for selected asthmatic children with mold sensitization for avoiding severe airway hyperresponsiveness.-
dc.format.extent9-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국환경보건학회-
dc.title곰팡이에 감작된 소아 천식 환자 가정내 환경유해물질 농도와 폐기능의 상관관계-
dc.title.alternativeThe Relationship between Indoor Air Pollutants and Pulmonary Function in Asthmatic Children with Mold Sensitization-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.5668/JEHS.2020.46.6.685-
dc.identifier.bibliographicCitation한국환경보건학회지, v.46, no.6, pp 685 - 693-
dc.citation.title한국환경보건학회지-
dc.citation.volume46-
dc.citation.number6-
dc.citation.startPage685-
dc.citation.endPage693-
dc.identifier.kciidART002661767-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorAsthma-
dc.subject.keywordAuthormold-
dc.subject.keywordAuthorenvironment-
dc.subject.keywordAuthorairway hyperresponsiveness-
dc.subject.keywordAuthorpulmonary function parameters-
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Pediatrics > 1. Journal Articles
4. Research institute > Institute for Healthcare Service Innovation > 1. Journal Articles
4. Research institute > Allergy Immunology Center > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Young photo

Yoo, Young
Anam Hospital (Department of Pediatrics, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE