Evaluation of the distance from the anterior cervicovaginal junction to the anterior peritoneal reflection for anterior colpotomy during vaginal hysterectomy in Korean women
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Ji Hye | - |
dc.contributor.author | Chae, Su Hyun | - |
dc.contributor.author | Lee, A. Jin | - |
dc.contributor.author | Min, Yoon Jung | - |
dc.contributor.author | So, Kyeong A. | - |
dc.contributor.author | Lee, Sun Joo | - |
dc.contributor.author | Kim, Tae Jin | - |
dc.contributor.author | Shim, Seung-Hyuk | - |
dc.date.accessioned | 2021-09-17T03:40:08Z | - |
dc.date.available | 2021-09-17T03:40:08Z | - |
dc.date.issued | 2021-08-20 | - |
dc.identifier.issn | 0025-7974 | - |
dc.identifier.issn | 1536-5964 | - |
dc.identifier.uri | https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/54249 | - |
dc.description.abstract | This study aimed to know the distance of the cervicovaginal junction (CVJ) to the anterior peritoneal reflection (APR) as measured in surgical specimens, and assess the distance between the CVJ and APR to ensure safe anterior colpotomy for vaginal hysterectomy among Korean women. Patients who underwent vaginal hysterectomy were included in the analysis. According to the presence of pelvic organ prolapse or menopausal status, the distance from the CVJ to the APR was assessed preoperatively through transvaginal ultrasonography (TV-US), as well as intraoperatively using surgical specimens. The intraclass correlation coefficient was used to determine the reliability between 2 measurements. In total, 171 patients were included. The median distance from the CVJ to the APR measured on TV-US was 19.8 (3.3-41.3) mm. Meanwhile, the median distance from the CVJ to the APR measured using the surgical specimen was 26.0 (12.0-55.0) mm. The intraclass correlation coefficient for the absolute agreement between 2 measurements was 0.353 (95% confidence interval: 0.002-0.570; P < .001), which is indicative of poor reliability. The median distance from the CVJ to the APR measured using the surgical specimen did not differ significantly between the 2 groups according to pelvic organ prolapse (26.0 [12.0-55.0] vs 27.5 [17.0-55.0] mm, P = .076] and menopausal status (27.0 [15.0-55.0] vs 26.0 [12.0-55.0] mm, P = .237). TV-US does not an accurately measure the dissection plane length from the CVJ to the APR during anterior colpotomy. During vaginal hysterectomy, the median distance from the CVJ to the APR measured using the surgical specimen was 26 (12.0-55.0) mm, which can help decrease surgical complications. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | LIPPINCOTT WILLIAMS & WILKINS | - |
dc.title | Evaluation of the distance from the anterior cervicovaginal junction to the anterior peritoneal reflection for anterior colpotomy during vaginal hysterectomy in Korean women | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1097/MD.0000000000026941 | - |
dc.identifier.wosid | 000685342600019 | - |
dc.identifier.bibliographicCitation | MEDICINE, v.100, no.33 | - |
dc.citation.title | MEDICINE | - |
dc.citation.volume | 100 | - |
dc.citation.number | 33 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | General & Internal Medicine | - |
dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
dc.subject.keywordPlus | ROUTE | - |
dc.subject.keywordAuthor | cervicovaginal incision | - |
dc.subject.keywordAuthor | laparoscopically assisted vaginal hysterectomy | - |
dc.subject.keywordAuthor | peritoneal reflection | - |
dc.subject.keywordAuthor | vaginal hysterectomy | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
73, Goryeodae-ro, Seongbuk-gu, Seoul, Republic of Korea (02841)82-2-2286-1265
COPYRIGHT 2020 KOREA UNIVERSITY MEDICAL LIBRARY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.