Detailed Information

Cited 10 time in webofscience Cited 0 time in scopus
Metadata Downloads

Interobserver variability in gross tumor volume delineation for hepatocellular carcinoma

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Young Suk-
dc.contributor.authorKim, Jun Won-
dc.contributor.authorYoon, Won Sup-
dc.contributor.authorKang, Min Kyu-
dc.contributor.authorLee, Ik Jae-
dc.contributor.authorKim, Tae Hyun-
dc.contributor.authorKim, Jin Hee-
dc.contributor.authorLee, Hyung-Sik-
dc.contributor.authorPark, Hee Chul-
dc.contributor.authorJang, Hong Seok-
dc.contributor.authorKay, Chul Seung-
dc.contributor.authorYoon, Sang Min-
dc.contributor.authorKim, Mi-Sook-
dc.contributor.authorSeong, Jinsil-
dc.date.available2020-11-02T10:49:00Z-
dc.date.issued2016-10-
dc.identifier.issn0179-7158-
dc.identifier.issn1439-099X-
dc.identifier.urihttps://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/5994-
dc.description.abstractPurpose There has been increasing use of external beam radiotherapy for localized treatment of hepatocellular carcinoma (HCC) with both palliative and curative intent. Quality control of target delineation in primary HCC is essential to deliver adequate doses of radiation to the primary tumor while preserving adjacent healthy organs. We analyzed interobserver variability in gross tumor volume (GTV) delineation for HCC. Patients and methods Twelve radiation oncologists specializing in liver malignancy participated in a multi-institutional contouring dummy-run study of nine HCC cases and independently delineated GTV on the same set of provided computed tomography images. Quantitative analysis was performed using an expectation maximization algorithm for simultaneous truth and performance level estimation (STAPLE) with kappa statistics calculating agreement between physicians. To quantify the interobserver variability of GTV delineations, the ratio of the actual delineated volume to the estimated consensus volume (STAPLE), the ratio of the common and encompassing volumes, and the coefficient of variation were calculated. Results The median kappa agreement level was 0.71 (range 0.28-0.86). The ratio of the actual delineated volume to the estimated consensus volume ranged from 0.19 to 1.93 (median 0.94) for all cases. The ratio of the common and encompassing volumes ranged from 0.001 to 0.56 (median 0.25). The coefficient of variation for GTV delineation ranged from 8 to 57% (median 26%). Conclusion The interobserver variability in target delineation of HCC GTV in this study is noteworthy. Multi-institution studies involving radiotherapy for HCC require appropriate quality assurance programs for target delineation.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherURBAN & VOGEL-
dc.titleInterobserver variability in gross tumor volume delineation for hepatocellular carcinoma-
dc.typeArticle-
dc.publisher.location독일-
dc.identifier.doi10.1007/s00066-016-1028-2-
dc.identifier.wosid000387138100005-
dc.identifier.bibliographicCitationSTRAHLENTHERAPIE UND ONKOLOGIE, v.192, no.10, pp 714 - 721-
dc.citation.titleSTRAHLENTHERAPIE UND ONKOLOGIE-
dc.citation.volume192-
dc.citation.number10-
dc.citation.startPage714-
dc.citation.endPage721-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOncology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryOncology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusCONSENSUS GUIDELINES-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusRADIATION-THERAPY-
dc.subject.keywordPlusCT-
dc.subject.keywordPlusDEFINITION-
dc.subject.keywordPlusRADIOTHERAPY-
dc.subject.keywordPlusIMPACT-
dc.subject.keywordPlusCANCER-
dc.subject.keywordPlusMRI-
dc.subject.keywordPlusREGISTRATION-
dc.subject.keywordAuthorOrgans at risk-
dc.subject.keywordAuthorRadiotherapy-
dc.subject.keywordAuthorChemoembolization-
dc.subject.keywordAuthorRadiofrequency ablation-
dc.subject.keywordAuthorQuality assurance-
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Radiation Oncology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Won Sup photo

Yoon, Won Sup
Ansan Hospital (Department of Radiation Oncology, Ansan Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE