Detailed Information

Cited 42 time in webofscience Cited 45 time in scopus
Metadata Downloads

Usefulness of Controlled Aliasing in Parallel Imaging Results in Higher Acceleration in Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging to Clarify the Hepatic Arterial Phase

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Yang Shin-
dc.contributor.authorLee, Chang Hee-
dc.contributor.authorKim, In Seong-
dc.contributor.authorKiefer, Berthold-
dc.contributor.authorWoo, Seung Tae-
dc.contributor.authorKim, Kyeong Ah-
dc.contributor.authorPark, Cheol Min-
dc.date.available2020-11-02T18:45:42Z-
dc.date.issued2014-03-
dc.identifier.issn0020-9996-
dc.identifier.issn1536-0210-
dc.identifier.urihttps://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/9533-
dc.description.abstractPurpose We aimed to determine whether the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique could improve the image quality of the hepatic arterial phase of gadoxetic acid-enhanced liver magnetic resonance (MR) imaging. Materials and Methods A total of 320 patients underwent gadoxetic acid-enhanced liver MR imaging: a conventional protocol (a fixed scan delay and 2-mL/s injection) using a standard 3-T MR system (Trio-Tim; Siemens, commercialized since 2005) (group A), an optimized protocol (bolus tracking and 1-mL/s injection) using a standard 3-T MR (group B), an optimized protocol using a new 3-T MR (Skyra; Siemens, commercialized since 2012) (group C), and an optimized protocol with CAIPIRINHA using a new 3-T MR (group D). The image quality of the hepatic arterial phase was graded using a 4-point rating scale from 1 (no artifacts) to 4 points (non-diagnostic images with severe artifacts). The differences in image quality scores among the 4 groups were evaluated. In addition, the detection rates of hypervascular hepatocellular carcinomas among the 4 groups were evaluated. Results Scores of 4 points were observed in groups A (n = 7), B (n = 5), and C (n = 3) but not in group D. The median image quality score was 2 in groups A and B and 1 in groups C and D. From group A to group D, the median image quality score decreased significantly (P = 0.0001). The median image quality score was significantly lower in group D than in groups A and B (P = 0.0001 and 0.001, respectively), whereas there was no significant difference observed between groups C and D (P = 0.656). The detection rates of hypervascular hepatocellular carcinomas on the hepatic arterial phase were not significantly different among the groups (all P > 0.03), except between groups A and D (P = 0.007). Conclusions The CAIPIRINHA technique improved the image quality of hepatic arterial phase imaging with gadoxetic acid, reducing the number of non-diagnostic arterial phase studies.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherLIPPINCOTT WILLIAMS & WILKINS-
dc.titleUsefulness of Controlled Aliasing in Parallel Imaging Results in Higher Acceleration in Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging to Clarify the Hepatic Arterial Phase-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1097/RLI.0000000000000011-
dc.identifier.scopusid2-s2.0-84894091067-
dc.identifier.wosid000331458800008-
dc.identifier.bibliographicCitationINVESTIGATIVE RADIOLOGY, v.49, no.3, pp 183 - 188-
dc.citation.titleINVESTIGATIVE RADIOLOGY-
dc.citation.volume49-
dc.citation.number3-
dc.citation.startPage183-
dc.citation.endPage188-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusBREATH-HOLD EXAMINATION-
dc.subject.keywordPlusPROTOCOL OPTIMIZATION-
dc.subject.keywordPlusLESION APPEARANCE-
dc.subject.keywordPlusDISODIUM-
dc.subject.keywordPlusMRI-
dc.subject.keywordPlusARTIFACTS-
dc.subject.keywordPlusQUALITY-
dc.subject.keywordAuthorgadoxetic acid-
dc.subject.keywordAuthorarterial phase-
dc.subject.keywordAuthorGd-EOB-DTPA-
dc.subject.keywordAuthorCAIPIRINHA-
dc.subject.keywordAuthorliver-
dc.subject.keywordAuthorMRI-
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Chang Hee photo

Lee, Chang Hee
Guro Hospital (Department of Radiology, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE