Detailed Information

Cited 22 time in webofscience Cited 24 time in scopus
Metadata Downloads

Set-up uncertainty during breast radiotherapy Image-guided radiotherapy for patients with initial extensive variation

Authors
Yang, D. S.Yoon, W. S.Chung, S. Y.Lee, J. A.Lee, S.Park, Y. J.Kim, C. Y.Son, G. S.
Issue Date
Apr-2013
Publisher
SPRINGER HEIDELBERG
Keywords
Breast cancer; Set-up error; Risk factor; Electronic portal image; Image-guided radiotherapy
Citation
STRAHLENTHERAPIE UND ONKOLOGIE, v.189, no.4, pp 315 - 320
Pages
6
Indexed
SCI
SCIE
SCOPUS
Journal Title
STRAHLENTHERAPIE UND ONKOLOGIE
Volume
189
Number
4
Start Page
315
End Page
320
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/10834
DOI
10.1007/s00066-012-0271-4
ISSN
0179-7158
1439-099X
Abstract
The aim of this work was to establish a customized strategy for image-guided radiotherapy during whole breast irradiation. Risk factors associated with extensive errors were assessed. A series of 176 consecutive breasts in 174 patients were retrospectively assessed. Electronic portal images from 914 medial and 807 lateral directions were reviewed. On the basis of the chest wall, the deviations between the simulation and each treatment were measured. The systematic (I ) pound and random error (sigma) of population, and the planning target volume (PTV) margin (2 I pound + 0.7 sigma) were calculated for each direction. Extensive set-up errors were defined as the fraction over the PTV margins in any direction. For extensive set-up errors, chi(2) tests and logistic regression analyses were conducted. The medial and lateral PTV margins for the right-left, superior-inferior, and anterior-posterior axes and the rotation of collimator were 2.6 and 2.4 mm, 4.6 and 4.6 mm, and 3.1 and 3.3 mm and 2.8 and 2.9 A degrees and cut-off values for extensive errors were 3, 5, and 4 mm and 3 A degrees, respectively. In chi(2) tests, tumor in upper outer quadrant (p = 0.012) and chest wall thickness a parts per thousand yenaEuro parts per thousand 2.0 cm (p = 0.003) for medial portals and age group (p = 0.036) for lateral portals were associated with extensive errors. In multivariate tests, the extensive error on the initial fraction had a high probability of extensive set-up errors in both medial (OR = 4.26, p < 0.001) and lateral portals (OR = 3.07, p < 0.001). In terms of the set-up uncertainty during breast irradiation, patients with extensive error in the initial treatment should be closely observed with serial image-guided radiotherapy.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Breast and Endocrine Surgery > 1. Journal Articles
2. Clinical Science > Department of Radiation Oncology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Suk photo

Lee, Suk
Anam Hospital (Department of Radiation Oncology, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE