Detailed Information

Cited 8 time in webofscience Cited 7 time in scopus
Metadata Downloads

Comparison of Spot versus Long Stenting for Femoropopliteal Artery Disease

Authors
Ko, Young-GukAhn, Chul-MinRha, Seung-WoonYu, Cheol WoongPark, Sang HoLee, Seung JinLee, Jae-HwanHer, Sung-HoKang, Woong CholCho, Young-SeokSeo, Jae-BinCho, Yun HyeongChoi, Donghoon
Issue Date
Jul-2019
Publisher
ELSEVIER SCIENCE INC
Citation
ANNALS OF VASCULAR SURGERY, v.58, pp 101 - 107
Pages
7
Indexed
SCI
SCIE
SCOPUS
Journal Title
ANNALS OF VASCULAR SURGERY
Volume
58
Start Page
101
End Page
107
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/1844
DOI
10.1016/j.avsg.2018.11.023
ISSN
0890-5096
1615-5947
Abstract
Background: Optimal stenting strategy for long femoropopliteal artery lesions still remains undefined. Longer stent length has been shown to be associated with increased risk of restenosis. We sought to compare the efficacy of spot versus long stenting in the treatment of femoropopliteal artery disease. Methods: This study was designed as a multicenter randomized controlled trial to compare immediate and mid-term outcomes of spot versus long primary stenting for femoropopliteal arterial lesions. A total of 125 patients were randomized 1: 1 to spot stenting group (n = 59) or long stenting group (n = 66). Results: All lesions were treated with self-expanding bare nitinol stents. Baseline clinical and lesion characteristics were similar between the 2 groups except for male gender and current smoker. The mean lesion length was 24.1 +/- 8.8 cm. Technical success was achieved in all patients. The 1-year primary patency and TLR-free (target lesion revascularization) survival did not differ significantly between the 2 groups. However, the spot stenting group showed a trend toward higher primary patency (86.1% vs. 72.7%, P = 0.158) and TLR-free survival (94.2% vs. 82.5%, P = 0.120). The total stented length (hazard ratio [HR] 1.01, 95% confidence interval [CI] 1.00-1.01, P = 0.011) and age (HR 0.94, 95% CI 0.90-1.00, P = 0.035) were independent predictors of restenosis. Conclusions: The spot stenting appears to be more favorable than the long stenting in terms of primary patency and TLR-free survival, although the difference was not statistically significant. The stented length was an independent predictor of restenosis.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Cardiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yu, Cheol Woong photo

Yu, Cheol Woong
Anam Hospital (Department of Cardiology, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE