Detailed Information

Cited 4 time in webofscience Cited 5 time in scopus
Metadata Downloads

Comparison of surgical correction rates between titanium and cobalt-chrome-alloy as rod materials in adolescent idiopathic scoliosis

Authors
Yang, Jae hyukSuh, Seung WooChang, Dong-Gune
Issue Date
Jun-2020
Publisher
Nature Research
Citation
Scientific Reports, v.10, no.1
Indexed
SCIE
SCOPUS
Journal Title
Scientific Reports
Volume
10
Number
1
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/28443
DOI
10.1038/s41598-020-66975-x
ISSN
2045-2322
Abstract
Numerous biomechanical studies comparing titanium (Ti) and cobalt-chrome-alloy (CCM) rods are described in the literature. However, there is a dearth of literature comparing the two rod materials in adolescent idiopathic scoliosis (AIS). Therefore, the purpose of this study is to compare the correction rates of Ti and CCM rods in the treatment of AIS with double major curves. We enrolled 45 patients with AIS who underwent surgery between 2009 and 2012. We divided patients into two groups, Group A (n = 29) treated with six-millimeter Ti rods and Group B (n = 16) treated with six-millimeter CCM rods. The rod-derotation maneuver was used for correction. We measured pre- and postoperative indices of coronal alignment (Cobb’s angle, coronal balance, T1-tilt, clavicle angle) and sagittal alignment (sagittal vertical axis, thoracic kyphosis, lumbar lordosis). In our study, there were no significant differences between the two groups with respect to demographics or curve characteristics (P > 0.05). In Group A, thoracic and lumbar curvature correction rates were 71.2% and 66.8% respectively, and in Group B they were 71.2% and 73.3%, respectively (P = 0.664 and 0.09). There were no significant differences between the two groups in coronal or sagittal factors (P > 0.05) except for greater postoperative lumbar lordosis in the CCM group (P < 0.001). In conclusion, Ti and CCM rods showed similar correction rates in the sagittal and coronal planes for the surgical correction of AIS with double major curves. Biomechanical studies of Ti and CCM rods in vitro is different in biological condition. © 2020, The Author(s).
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Orthopedic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yang, Jae hyuk photo

Yang, Jae hyuk
Anam Hospital (Department of Orthopedic Surgery, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE