Abstract
Background Intramedullary hip nails may be classified as blades or screws depending on the type of lag screw used. Recently, a combination of lag screw types with a U-clip insertion has also been used. The purpose of this study was to evaluate the clinical and radiological outcomes of these new screw types. Methods A total of 185 patients with trochanteric femoral fractures (age ≥ 65 years) who underwent surgery with intramedullary nails were selected. Surgeries with InterTrochanteric/SubTrochanteric (ITST), Proximal Femoral Nail Antirotation (PFNA), and Gamma 3 U-Blade lag screws were performed between January 2011 and June 2016. The AO/OTA classification, presence of a basicervical fracture type on 3D-CT, BMI, BMD, reduction quality, position of the lag screw, TAD (tip apex distance) of the lag screw, sliding distance of the lag screw, varus change (neck shaft angle), radiological union period, fixation failure and functional outcome as determined by walking ability were analyzed. Results There were 3/60 (5.0%) cases of fixation failure in the ITST group, all caused by cut-out; 4/57 (7.0%) in the PFNA II group: 3 caused by cut-through and 1 by metal fracture; 1/68 (1.5%) in the Gamma 3 U-Blade lag screw group (P = 0.301). In each group, the sliding distance of the lag screw showed a significant difference (P = 0.017), whereas significant sliding over 10 mm showed no statistically significant results. Conclusion There was only one (1.5%) case of fixation failure in the Gamma 3 U-Blade lag screw group. The sliding distance of the U-Blade was found to be in the middle, between the PFNA II (shorter) and ITST (longer) implants. The new rotational control lag screw seems to be comparable to other screw types.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Orthopedic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sang Min photo

Kim, Sang Min
Guro Hospital (Department of Orthopedic Surgery, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE