Detailed Information

Cited 30 time in webofscience Cited 34 time in scopus
Metadata Downloads

Fluorescence-based immunosensor using three-dimensional CNT network structure for sensitive and reproducible detection of oral squamous cell carcinoma biomarker

Authors
Song, Chung KilOh, EunkyulKang, Min SungShin, Bum SeokHan, Soo YoungJung, MingiLee, Eui SeokYoon, Soo-YoungSung, Myung MoNg, Wei BengCho, Nam-JoonLee, Haiwon
Issue Date
16-Oct-2018
Publisher
ELSEVIER SCIENCE BV
Keywords
Cyfra 21-1; Fluorescence-based immunoassay; Oral squamous cell carcinoma; 3DN-CNTs; Biosensor
Citation
ANALYTICA CHIMICA ACTA, v.1027, pp 101 - 108
Pages
8
Indexed
SCI
SCIE
SCOPUS
Journal Title
ANALYTICA CHIMICA ACTA
Volume
1027
Start Page
101
End Page
108
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/3025
DOI
10.1016/j.aca.2018.04.025
ISSN
0003-2670
1873-4324
Abstract
A hierarchical three-dimensional network of carbon nanotubes on Si pillar substrate (3DN-CNTs) was developed for the accurate detection of oral squamous cell carcinoma (OSCC) in clinical saliva samples. The 3DN-CNTs were uniformly coated with a layer of aluminum oxides to enhance structural stability during biomarker detection. Cytokeratin-19 antigen (Cyfra 21-1) was utilized as a model biomarker of OSCC for fluorescence-based immunosensor using 3DN-CNTs (3DN-CNTs sensor). The 3DN-CNTs sensor enhances the sensitivity of Cyfra 21-1 detection by increasing the density of immobilized antibody through high surface area of 3DN-CNTs and enhancing the accessibility of biomolecules through the ordered pathway of hierarchical structure. The reliable detection limit for sensing of Cyfra 21-1 was estimated as in the level of 0.5 ng/mL and the quantitative estimation of Cyfra 21-1 was analyzed by 4parameter logistic (4-PL) model for curve-fitting analysis. Clinical applicability of 3DN-CNTs sensor was evaluated through correlation with the commercially available electrochemiluminescence (ECL) detection system in the hospital. The assay results of the two systems for clinical saliva samples showed a good linear correlation. The 3DN-CNTs sensor offers great potential for accurate diagnosis of OSCC using Cyfra 21-1 biomarker in clinical fluids. (C) 2018 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Laboratory Medicine > 1. Journal Articles
2. Clinical Science > Department of Oral and Maxillofacial Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Soo Young photo

Yoon, Soo Young
Guro Hospital (Department of Laboratory Medicine, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE