Detailed Information

Cited 1 time in webofscience Cited 2 time in scopus
Metadata Downloads

Analyses of vessel densities and foveal avascular zones using four optical coherence tomography angiography devices

Authors
Park, S.Y.Nam, Ki TaeYun, Cheol minJang, S.
Issue Date
May-2020
Publisher
Korean Ophthalmological Society (KOS)
Keywords
Foveal avascular zone; Optical coherence tomography angiography; Vessel density
Citation
Journal of Korean Ophthalmological Society, v.61, no.5, pp 482 - 490
Pages
9
Indexed
SCOPUS
ESCI
KCI
Journal Title
Journal of Korean Ophthalmological Society
Volume
61
Number
5
Start Page
482
End Page
490
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/33078
DOI
10.3341/jkos.2020.61.5.482
ISSN
0378-6471
2092-9374
Abstract
Purpose: To compare the vessel density (VD) and foveal avascular zone (FAZ) area using four different optical coherence tomography angiography (OCTA) images. Methods: This prospective study analyzed the OCTA images of consecutive healthy subjects using Plex-Elite (Carl Zeiss), DRI OCT-1 Atlantis (Topcon), AngioPlex (Carl Zeiss), and Spectralis OCTA (Heidelberg Engineering). The VD and FAZ areas were calculated using the OCTA images with a 3 x 3 mm2 volume scan pattern centered on the fovea. Results: The VD (%) of the superficial capillary plexus (SCP) and deep capillary plexus (DCP) were different using the four devices: Plex-Elite (42.17 ± 2.79, 43.71 ± 2.36), DRI OCT-1 Atlantis (28.70 ± 2.87, 30.27 ± 3.02), AngioPlex (28.32 ± 6.68, 33.33 ± 5.44), and Spectralis OCTA (27.86 ± 4.13, 28.54 ± 3.14), respectively; p < 0.001). The FAZ area (mm2) of the SCP and DCP were different using the four devices: Plex-Elite (0.276 ± 0.097, 0.340 ± 0.100), DRI OCT-1 Atlantis (0.281 ± 0.102, 0.354 ± 0.119), AngioPlex (0.269 ± 0.099, 0.422 ± 0.120), and Spectralis OCTA (0.272 ± 0.079, 0.298 ± 0.106), respectively; p < 0.001). The VD of the SCP and DCP had no significant correlation using the four devices (all, p > 0.05), but the FAZ area had positive correlations using the four devices (all, p < 0.001). Conclusions: The four OCTA devices provided different VD and FAZ areas, so these differences should be considered in analyzing OCTA images. © 2020 The Korean Ophthalmological Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Ophthalmology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yun, Cheol min photo

Yun, Cheol min
Ansan Hospital (Department of Ophthalmology, Ansan Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE