Detailed Information

Cited 44 time in webofscience Cited 56 time in scopus
Metadata Downloads

Comparison of sirolimus-eluting stent, paclitaxel-eluting stent, and bare metal stent in the treatment of long coronary lesions

Authors
Kim, YHPark, SWLee, CWHong, MKGwon, HCJang, YLee, MMKoo, BKOh, DJSeung, KBTahk, SJYoon, JPark, SJ
Issue Date
Feb-2006
Publisher
WILEY
Keywords
stent; restenosis; coronary artery disease
Citation
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, v.67, no.2, pp 181 - 187
Pages
7
Indexed
SCIE
SCOPUS
Journal Title
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
Volume
67
Number
2
Start Page
181
End Page
187
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/36146
DOI
10.1002/ccd.20586
ISSN
1522-1946
1522-726X
Abstract
Objective: This study compared the efficacy of the sirolimus-eluting stent (SES), the paclitaxel-eluting stent (PES), and the bare metal stent (BMS) for long coronary lesions. Background: The outcome of drug-eluting stent (DES) implantation in long coronary lesions remains unclear. Methods: The study involved 527 patients with de novo long coronary lesions (>= 24 mm), which were treated with long (>= 28 mm) SESs (223 lesions), PESs (194 lesions), or BMSs (201 lesions). Results: Lesions in the SES (36.0 +/- 14.9 mm, P < 0.001) and PES (36.3 +/- 14.5 mm, P < 0.001) groups were longer than those in the BMS group (32.0 +/- 12.3 mm), meaning the two DES groups had longer stented segments than did the BMS group. Six-month angiographic follow-up showed the SES (9.3%, P < 0.001) and PES (21.3%, P < 0.001) groups had lower in-segment restenosis rates than that of the BMS group (42.5%). The rate of major adverse cardiac events (MACE) including death, myocardial infarction, and target lesion revascularization at 9 months was higher in the BMS group (26.6%) than that in the SES (13.0%, P < 0.001) and PES (15.7%, < 0.001) groups. Posthoc analysis of the two DES groups showed that the in-segment restenosis rate was lower for the SES than that for the PES group (P = 0.002), while the MACE rate was similar. Conclusions: The use of DESs for long coronary lesions appears to be safe and more effective than the use of BMSs in terms of restenosis and adverse clinical events. SES use was associated with lower late luminal loss and a lower angiographic restenosis rate compared with PES use. (c) 2006 Wiley-Liss, Inc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Cardiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Dong Joo photo

Oh, Dong Joo
Guro Hospital (Department of Cardiology, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE