Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

저작압이 임프란트 주위골 내 응력분포에 미치는 영향에 관한 연구AN ANALYSIS OF STRESS DISTRIBUTION AROUND THE IMPLANT ACCORDING TO THE BONE QUALITY AND BITE FORCE: FINITE ELEMENT METHOD

Other Titles
AN ANALYSIS OF STRESS DISTRIBUTION AROUND THE IMPLANT ACCORDING TO THE BONE QUALITY AND BITE FORCE: FINITE ELEMENT METHOD
Authors
현기봉이선형장익태양재호신상완
Issue Date
Apr-2001
Publisher
대한치과보철학회
Keywords
Implant; Bone quality; Bite force; Finite element; Stress
Citation
대한치과보철학회지, v.39, no.4, pp 323 - 344
Pages
22
Indexed
KCICANDI
Journal Title
대한치과보철학회지
Volume
39
Number
4
Start Page
323
End Page
344
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/37300
ISSN
0301-2875
2005-3789
Abstract
Since the early study about the osseointegration, lots of researches have been performed to increase the success rate and the stress around the implant in the jaw bone has been considered as one of the causes of failure. The purpose of this study was to examine the relationship between the implant failure and the stress by analysing the influence of different bone quality and bite force of some foods on the stress distribution around the implant, and to estimate the treatment result according to the bone quality and dietary pattern of patients. Bone quality was divided in 4 groups and models were drawn with the assumption that thread type implant(Nobel Biocare AB, Goteborg, Sweden) of 3.75mm diameter, 13mm length was installed to the bones. Various bite forces were applied to the occlusal surface of superstructure and the stress distributed around the implant were analysed with finite element analysis program. The results were as follows ; 1. The stress was changed proportionally to the bite forces of foods at all measuring points in all load cases. 2. The stress at the marginal bone was higher than that of the other measuring points in all load cases, and it was decreased at the first thread area. 3. The stress at the marginal bone was highest in type IV bone in all load cases. Especially it was twice those of other bone types at the bucco-lingual marginal bone and 50% higher at the mesio-distal marginal bone. 4. The stress at the bucco-lingual sides of the bone around the apical portions of implant showed little differences among the bone types, while type IV bone showed lower stress concentration than the other bone types in the mesio-distal sides. 5. Under the buccal oblique load ( ), the stress at the lingual marginal bone was higher than that of buccal marginal bone, and the difference between the two points was almost same regardless of bone types.
Files in This Item
Go to Link
Appears in
Collections
2. Clinical Science > Department of Dentistry > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Sang Wan photo

Shin, Sang Wan
Guro Hospital (Department of Dentistry, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE