Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Optimal placement of needle electromyography in extensor indicis: A cadaveric study

Authors
Im J.Y.Park H.B.Lee S.J.Lim S.G.Kim K.H.Kim D.Rhyu I.J.Park B.K.Kim D.H.
Issue Date
2018
Publisher
Korean Academy of Rehabilitation Medicine
Keywords
Cadaver; Electrodiagnosis; Electromyography; Extensor indicis; Needles
Citation
Annals of Rehabilitation Medicine, v.42, no.3, pp 473 - 476
Pages
4
Indexed
SCOPUS
ESCI
KCI
Journal Title
Annals of Rehabilitation Medicine
Volume
42
Number
3
Start Page
473
End Page
476
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/4152
DOI
10.5535/arm.2018.42.3.473
ISSN
2234-0645
2234-0653
Abstract
Objective To identify the center of extensor indicis (EI) muscle through cadaver dissection and compare the accuracy of different techniques for needle electromyography (EMG) electrode insertion. Methods Eighteen upper limbs of 10 adult cadavers were dissected. The center of trigonal EI muscle was defined as the point where the three medians of the triangle intersect. Three different needle electrode insertion techniques were introduced: M1, 2.5 cm above the lower border of ulnar styloid process (USP), lateral aspect of the ulna; M2, 2 finger breadths (FB) proximal to USP, lateral aspect of the ulna; and M3, distal fourth of the forearm, lateral aspect of the ulna. The distance from USP to the center (X) parallel to the line between radial head to USP, and from medial border of ulna to the center (Y) were measured. The distances between 3 different points (M1- M3) and the center were measured (marked as D1, D2, and D3, respectively). Results The median value of X was 48.3 mm and that of Y was 7.2 mm. The median values of D1, D2 and D3 were 23.3 mm, 13.3 mm and 9.0 mm, respectively. Conclusion The center of EI muscle is located approximately 4.8 cm proximal to USP level and 7.2 mm lateral to the medial border of the ulna. Among the three methods, the technique placing the needle electrode at distal fourth of the forearm and lateral to the radial side of the ulna bone (M3) is the most accurate and closest to the center of the EI muscle. ©2018 by Korean Academy of Rehabilitation Medicine.
Files in This Item
There are no files associated with this item.
Appears in
Collections
1. Basic Science > Department of Anatomy > 1. Journal Articles
2. Clinical Science > Department of Physical Medicine and Rehabilitation > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Rhyu, Im Joo photo

Rhyu, Im Joo
College of Medicine (Department of Anatomy)
Read more

Altmetrics

Total Views & Downloads

BROWSE