Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Comparison of a new enzymatic assay for serum homocysteine on Toshiba TBA-c16000 against an immunoassay on Abbott Architect

Authors
Kim, Ha NuiYoon, Soo-Young
Issue Date
Feb-2021
Publisher
Taylor & Francis
Keywords
Homocysteine; enzymatic assay; immunoassay; spectrophotometric; method comparison
Citation
Scandinavian Journal of Clinical and Laboratory Investigation, v.81, no.1, pp 46 - 51
Pages
6
Indexed
SCIE
SCOPUS
Journal Title
Scandinavian Journal of Clinical and Laboratory Investigation
Volume
81
Number
1
Start Page
46
End Page
51
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/51640
DOI
10.1080/00365513.2020.1852597
ISSN
0036-5513
1502-7686
Abstract
Homocysteine, a risk factor for cardiovascular disease, is commonly analyzed using enzymatic measurements and immunoassays. We compared the results of a new enzymatic assay with those of an immunoassay, using new reagents for homocysteine. The 87 serum samples were analyzed using the Abbott Architect i2000sr (immunoassay) and Toshiba TBA-c16000 (enzymatic assay), and the results obtained from the two assays were compared for precision, correlation, linearity, sample carryover, and reference range verification according to the Clinical and Laboratory Standards Institute guidelines. Repeatability and total imprecision were within the desirable range (Westgard QC, 4.15%). Correlation analysis revealed a strong correlation with a slope ranging from 0.9887 to 1.052, a correlation coefficient (R (2)) of 0.9886 [95% confidence interval (CI) of 0.9899-0.9968], and a y-intercept from -0.5741 to 0.6252. Linearity was acceptable (R (2) = 0.9993), and the recovery rate was within +/- 10% of the expected value. The enzymatic assay showed an acceptable carryover rate (-0.15%) and a shorter turnaround time (10-12 min) compared with that of the immunoassay (30 min). Our new enzymatic assay for the measurement of homocysteine showed an acceptable performance in terms of precision, correlation, linearity, carryover test, cost-effectiveness, and speed.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Laboratory Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ha Nui photo

Kim, Ha Nui
Guro Hospital (Department of Laboratory Medicine, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE