Could both intrinsic and extrinsic iodine be successfully suppressed on virtual non-contrast CT images for detecting thyroid calcification?

Authors
Park, ArimLee, Young HenSeo, Hyung Suk
Issue Date
Jun-2021
Publisher
SPRINGER
Keywords
Thyroid; Dual-energy computed tomography (DECT); Iodine concentration
Citation
JAPANESE JOURNAL OF RADIOLOGY, v.39, no.6, pp 580 - 588
Pages
9
Indexed
SCIE
SCOPUS
Journal Title
JAPANESE JOURNAL OF RADIOLOGY
Volume
39
Number
6
Start Page
580
End Page
588
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/52174
DOI
10.1007/s11604-021-01095-8
ISSN
1867-1071
1867-108X
Abstract
Purpose Although virtual non-contrast (VNC) successfully removes iodinated contrast, uncertainty exists regarding the feasibility of VNC to suppress iodine for detecting thyroid calcification. Therefore, we evaluated whether both intrinsic and extrinsic iodine attenuation were suppressed on VNC images. Material and methods We enrolled 128 patients (male: female 17:111; age 48.0 +/- 10.4 years) who underwent dual-layer dual-energy CT (DL-DECT) examination before their thyroid cancer surgeries. Two additional sets of VNC (VNCu, VNCc) images were retrospectively generated from their true unenhanced (TUE) and true contrast-enhanced (TCE) series. We compared CT attenuation values measured on the VNCu and VNCc images by drawing identical regions of interest encompassing thyroid parenchyma, then subjectively determined the concordance of calcification. Results Although CT attenuation discrepancies between the VNCu and VNCc were significant (2.0 +/- 5.7HU, p < 0.001),61.7%, 89.1%, and 100.0% of all measurements were < 5HU, < 10HU, and < 15HU. Based on Bland-Altman analysis, the limits of agreement were - 9.2HU and 13.2HU, whereas the proportional differences were small for VNC images generated from both TUE and TCE images. There was no discordance between two VNC image sets in detecting thyroid calcification. Conclusions VNC technique could be a feasible method to suppress both intrinsic and extrinsically administered iodine for detecting thyroid calcification
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Young Hen photo

Lee, Young Hen
Ansan Hospital (Department of Radiology, Ansan Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE