Detailed Information

Cited 7 time in webofscience Cited 5 time in scopus
Metadata Downloads

Efficacy and safety of penile girth enhancement using hyaluronic acid filler and the clinical impact on ejaculation: A multi-center, patient/ evaluator-blinded, randomized active-controlled trial

Authors
Ahn, Sun TaeShim, Ji SungBae, Woong JinKim, Sae WoongKim, Je JongMoon, Du Geon
Issue Date
Apr-2022
Publisher
Korean Society for Sexual Medicine and Andrology
Keywords
Ejaculation; Filler; Girth enhancement; Hyaluronic acid; Penis
Citation
World Journal of Men's Health, v.40, no.2, pp 299 - 307
Pages
9
Indexed
SCIE
SCOPUS
KCI
Journal Title
World Journal of Men's Health
Volume
40
Number
2
Start Page
299
End Page
307
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/53827
DOI
10.5534/WJMH.210007
ISSN
2287-4208
2287-4690
Abstract
Purpose We aimed to evaluate the efficacy and safety of penile girth enhancement (PGE) using hyaluronic acid (HA) filler with different physical properties from previous studies. Additionally, we evaluated the clinical impact on ejaculation after PGE. Materials and Methods This was a prospective, patient/evaluator-blinded, randomized, active-controlled, multicenter trial. Patients recruited between December 2017 and March 2018 were randomly assigned to the HA filler or control group (polylactic acid [PLA] filler). Penile girth, satisfaction level, Premature Ejaculation Profile (PEP), and self-estimated intravaginal ejaculation latency time (IELT) were assessed at baseline and at 24 weeks post-injection. Results Sixty-four subjects (32 in each group) completed the trial. The mean increase in girth was 22.74±12.60 mm and 20.23±8.73 mm in the HA and control groups, respectively. Satisfaction level regarding penile appearance and sexual life significantly increased in both groups. There was no statistically significant difference between the groups in terms of increase in penile girth or change in satisfaction level. Both groups showed significant improvements in PEP index scores. Self-estimated IELT also significantly increased in the HA group (from 5.36±3.51 to 7.86±4.73 minutes, p=0.0001) and control group (from 5.23±3.55 to 6.43±4.22 minutes, p=0.021). No serious adverse events (AEs) were reported. Conclusions PGE with HA and PLA fillers resulted in significant enhancement of girth without serious AEs with no significant differences. Furthermore, PGE using filler improved clinical symptoms related to ejaculation.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Urology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Sun Tae photo

Ahn, Sun Tae
Guro Hospital (Department of Urology, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE