Detailed Information

Cited 16 time in webofscience Cited 16 time in scopus
Metadata Downloads

Lab on a chip-based hepatic sinusoidal system simulator for optimal primary hepatocyte culture

Authors
Choi, Yoon YoungKim, JaehyungLee, Sang-HoonKim, Dong-Sik
Issue Date
Aug-2016
Publisher
SPRINGER
Keywords
Hepatocyte; Microfluidic; Shear stress; Spheroid
Citation
BIOMEDICAL MICRODEVICES, v.18, no.4
Indexed
SCIE
SCOPUS
Journal Title
BIOMEDICAL MICRODEVICES
Volume
18
Number
4
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/6231
DOI
10.1007/s10544-016-0079-6
ISSN
1387-2176
1572-8781
Abstract
Primary hepatocyte cultures have been used in studies on liver disease, physiology, and pharmacology. While they are an important tool for in vitro liver studies, maintaining liver-specific characteristics of hepatocytes in vitro is difficult, as these cells rapidly lose their unique characteristics and functions. Portal flow is an important condition to preserve primary hepatocyte functions and liver regeneration in vivo. We have developed a microfluidic chip that does not require bulky peripheral devices or an external power source to investigate the relationship between hepatocyte functional maintenance and flow rates. In our culture system, two types of microfluidic devices were used as scaffolds: a monolayer- and a concave chamber-based device. Under flow conditions, our chips improved albumin and urea secretion rates after 13 days compared to that of the static chips. Reverse transcription polymerase chain reaction demonstrated that hepatocyte-specific gene expression was significantly higher at 13 days under flow conditions than when using static chips. For both two-dimensional and three-dimensional culture on the chips, flow resulted in the best performance of the hepatocyte culture in vitro. We demonstrated that flow improves the viability and efficiency of long-term culture of primary hepatocytes and plays a key role in hepatocyte function. These results suggest that this flow system has the potential for long-term hepatocyte cultures as well as a technique for three-dimensional culture.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Hepato-Biliary-Pancreatic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Dong-Sik photo

Kim, Dong-Sik
Anam Hospital (Department of Hepato-Biliary-Pancreatic Surgery, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE