Evaluation of the dosimetric accuracy for a couch-based tracking system (CBTS)

Authors
Chang, Kyung HwanLee, SukKim, Kwang HyeonShim, Jang BoYang, Dae SikPark, Young JeYoon, Won SupKim, Chul YongCao, Yuanjie
Issue Date
Jul-2016
Publisher
KOREAN PHYSICAL SOC
Keywords
Robotic couch; Tumor tracking; Patient motion; Dosimetric accuracy; Gel dosimeter
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.69, no.2, pp 241 - 247
Pages
7
Indexed
SCI
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
69
Number
2
Start Page
241
End Page
247
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/6279
DOI
10.3938/jkps.69.241
ISSN
0374-4884
1976-8524
Abstract
In this study, the geometric and dosimetric accuracy of an in-house-developed couch-based tracking system (CBTS) was investigated using both film and in-house-developed polymer gel dosimeters. We evaluated the 1D and the 2D motion accuracies of our couch system by using Gafchromic EBT film. For the 1D test, the couch system was moved 5, 10, and 20 mm in the X, Y, and Z directions, respectively. Meanwhile, for the 2D test, it was moved along the XY, YZ, and ZX directions. We compared the profiles, full widths at half maximum (FWHMs), and penumbras between the static and the tracking fields. For the 3D test, we quantitatively compared the dose distribution between the static and the tracking fields by using the polymer gel dosimeter when it was simultaneously moved in the XYZ directions. We confirmed that the film was moved according to motion amplitudes of 5, 10, and 20 mm in the X, Y, and Z directions, respectively, in the 1D and 2D motion tests. The value of the FWHM of the static field and the three tracking fields were 51.88, 53.28, 57.67, and 64.43 mm, respectively. Two types of penumbras became wider with increasing amplitudes compared to the static field. For the 3D test, the dose distribution of the XYZ tracking field was qualitatively larger than that of the static field. We conclude that this CBTS has the potential for pre-clinical applications in adaptive radiation therapy.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Radiation Oncology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yang, Dae Sik photo

Yang, Dae Sik
Guro Hospital (Department of Radiation Oncology, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE