Optimal hemoglobin level for anemia treatment in a cohort of hemodialysis patients
- Authors
- Jung M.Y.; Hwang S.Y.; Hong Y.A.; Oh S.Y.; Seo J.H.; Lee Y.M.; Park S.W.; Kim J.S.; Wang J.K.; Kim J.Y.; Lee J.E.; Ko G.J.; Pyo H.J.; Kwon Y.J.
- Issue Date
- 2015
- Publisher
- Elsevier
- Keywords
- Anemia; Hemodialysis; Hemoglobin; Mortality
- Citation
- Kidney Research and Clinical Practice, v.34, no.1, pp 20 - 27
- Pages
- 8
- Indexed
- SCOPUS
KCI
- Journal Title
- Kidney Research and Clinical Practice
- Volume
- 34
- Number
- 1
- Start Page
- 20
- End Page
- 27
- URI
- https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/8452
- DOI
- 10.1016/j.krcp.2014.11.003
- ISSN
- 2211-9132
2211-9140
- Abstract
- Background Anemia is a major risk factor that contributes to mortality in patients with chronic kidney disease. There is controversy over the optimal hemoglobin (Hb) target in these patients. This study investigated the association between Hb level and mortality in a cohort of hemodialysis (HD) patients in Korea. Methods This study was a multicenter prospective observational study of maintenance HD patients that was performed for 5 years in western Seoul, Korea. Three hundred and sixty-two participants were enrolled. Laboratory values and mortality were accessed every 6 months. Repeated measures of laboratory values in each interval were averaged to obtain one semiannual mean value. The Hb values were divided into six groups: (1) Hb<9 g/dL; (2) 9 g/dL≤ Hb<10 g/dL; (3) 10 g/dL≤ Hb;Hb<11 g/dL; (4) 11 g/dL≤ Hblt&12 g/dL; (5) 12 g/dL≤ Hb;Hb<13 g/dL; and (6) Hb≥ 13 g/dL. We analyzed the odds ratio for all-cause mortality, based on the Hb group, and adjusted for demographics and various laboratory values. Statistics were performed with SAS, version 9.1 software (SAS Institute Inc., Cary, NC, USA). Results Mortality odds ratios relative to the reference group (10-11 g/dL) in the fully adjusted model were 3.61 for<9 g/dL; 3.17 for 9-10 g/dLz.ast;; 4.65 for 11-12 g/dLz.ast;; 5.50 for 12-13 g/dLz.ast;; and 2.05 for 13 g/dL (z.ast; indicates P<0.05). Conclusion In this study, a Hb level of 10-11 g/dL was associated with the lowest mortality among the groups with Hb level<13 g/dL. Larger interventional trials are warranted to determine the optimal Hb target for Korean HD patients. © 2015. The Korean Society of Nephrology. Published by Elsevier. All rights reserved.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 2. Clinical Science > Department of Nephrology and Hypertension > 1. Journal Articles