Compressed Deep Learning to Classify Arrhythmia in an Embedded Wearable Device

Authors
Lee, Kwang-SigPark, Hyun-JoonKim, Ji EonKim, Hee JungChon, SangilKim, SangkyuJang, JaesungKim, Jin-KookJang, SeongbinGil, YeongjoonSon, Ho Sung
Issue Date
Mar-2022
Publisher
Multidisciplinary Digital Publishing Institute (MDPI)
Keywords
arrhythmia; compressed deep learning; embedded wearable device; Resnet; Mobilenet
Citation
Sensors, v.22, no.5
Indexed
SCIE
SCOPUS
Journal Title
Sensors
Volume
22
Number
5
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2021.sw.kumedicine/55508
DOI
10.3390/s22051776
ISSN
1424-8220
1424-8220
Abstract
The importance of an embedded wearable device with automatic detection and alarming cannot be overstated, given that 15-30% of patients with atrial fibrillation are reported to be asymptomatic. These asymptomatic patients do not seek medical care, hence traditional diagnostic tools including Holter are not effective for the further prevention of associated stroke or heart failure. This is likely to be more so in the era of COVID-19, in which patients become more reluctant on hospitalization and checkups. However, little literature is available on this important topic. For this reason, this study developed efficient deep learning with model compression, which is designed to use ECG data and classify arrhythmia in an embedded wearable device. ECG-signal data came from Korea University Anam Hospital in Seoul, Korea, with 28,308 unique patients (15,412 normal and 12,896 arrhythmia). Resnets and Mobilenets with model compression (TensorFlow Lite) were applied and compared for the diagnosis of arrhythmia in an embedded wearable device. The weight size of the compressed model registered a remarkable decrease from 743 MB to 76 KB (1/10000), whereas its performance was almost the same as its original counterpart. Resnet and Mobilenet were similar in terms of accuracy, i.e., Resnet-50 Hz (97.3) vs. Mo-bilenet-50 Hz (97.2), Resnet-100 Hz (98.2) vs. Mobilenet-100 Hz (97.9). Here, 50 Hz/100 Hz denotes the down-sampling rate. However, Resnets took more flash memory and longer inference time than did Mobilenets. In conclusion, Mobilenet would be a more efficient model than Resnet to classify arrhythmia in an embedded wearable device.
Files in This Item
There are no files associated with this item.
Appears in
Collections
4. Research institute > Institute for Healthcare Service Innovation > 1. Journal Articles
4. Research institute > Institute of Human Behavior and Genetics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Eon photo

Kim, Ji Eon
Anam Hospital (Department of Thoracic and Cardiovascular Surgery, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE