Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of Four Systems for SARS-CoV-2 Antibody at Three Time Points after SARS-CoV-2 Vaccinationopen access

Authors
Seo, Jong DoNam, MinjeongLee, Tae HwanAhn, Yeon-SunShin, Seon-HyeonHan, Hye YoungMoon, Hee-Won
Issue Date
Jun-2022
Publisher
MDPI AG
Keywords
SARS-CoV-2; vaccination; antibody; assays
Citation
Diagnostics, v.12, no.6
Indexed
SCIE
SCOPUS
Journal Title
Diagnostics
Volume
12
Number
6
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2021.sw.kumedicine/61165
DOI
10.3390/diagnostics12061349
ISSN
2075-4418
Abstract
Background: Immunity against severe acute respiratory syndrome coronavirus 2 (SARSCoV-2) wanes over time after vaccination. Methods: We compared SARS-CoV-2 antibody levels in serial samples from 350 vaccinated individuals at 3 time points (3 weeks after the first or second dose and before the third dose) with 4 assays: GenScript cPASS SARS-CoV-2 neutralization antibody detection kits (cPASS), Siemens SARS-CoV-2 IgG (sCOVG), Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II), and an Immuno-OnTM COVID-19 IgG test (Immuno-On IgG). Antibody levels by time, concordance between assays, and values from other tests corresponding to the percent inhibition results in cPASS were assessed. Results: The median values at three time points were 49.31%, 90.87%, and 53.38% inhibition for cPASS, 5.39, 13.65, and 2.24 U/mL for sCOVG, 570.25, 1279.65, and 315.80 AU/mL for CoV-2 IgG II, and 223.22, 362.20, and 62.20 relative units (RU) for Immuno-On IgG. The concordance with cPASS at each time point ranged from 0.735 to 0.984, showing the highest concordance in the second sample and lowest concordance in the third in all comparative tests. The values corresponded to 30% inhibition, and the cutoffs of cPASS, were 2.02 U/mL, 258.6 AU/mL, and 74.2 RU for each test. Those for 50%, 70%, and 90% inhibition were 3.16, 5.66, and 8.26 U/mL for sCOVG, while they were 412.5, 596.9, and 1121.6 AU/mL for CoV-2 IgG II and 141.8, 248.92, and 327.14 RU for Immuno-On IgG. Conclusions: This study demonstrated the dynamic changes in antibody values at different time points using four test systems and is expected to provide useful baseline data for comparative studies and standardization efforts in the future.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Laboratory Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Nam, Min Jeong photo

Nam, Min Jeong
Anam Hospital (Department of Laboratory Medicine, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE