Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Modified intraocular lens power selection method according to biometric subgroups Eom IOL power calculatoropen access

Authors
Eom, YoungsubBae, So HyeonYang, Seul KiKim, Dong HyunSong, Jong SukCooke, David L.
Issue Date
Feb-2024
Publisher
Nature Publishing Group
Keywords
Intraocular lens; Power; Biometry; Calculation; Formula
Citation
Scientific Reports, v.14, no.1
Indexed
SCIE
SCOPUS
Journal Title
Scientific Reports
Volume
14
Number
1
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2021.sw.kumedicine/65804
DOI
10.1038/s41598-024-54346-9
ISSN
2045-2322
Abstract
This study evaluates the accuracy of a newly developed intraocular lens (IOL) power calculation method that applies four different IOL power calculation formulas according to 768 biometric subgroups based on keratometry, anterior chamber depth, and axial length. This retrospective cross-sectional study was conducted in at Korea University Ansan Hospital. A total of 1600 eyes from 1600 patients who underwent phacoemulsification and a ZCB00 IOL in-the-bag implantation were divided into two datasets: a reference dataset (1200 eyes) and a validation dataset (400 eyes). Using the reference dataset and the results of previous studies, the Eom IOL power calculator was developed using 768 biometric subgroups. The median absolute errors (MedAEs) and IOL Formula Performance Indexes (FPIs) of the Barrett Universal II, Haigis, Hoffer Q, Holladay 1, Ladas Super, SRK/T, and Eom formulas using the 400-eye validation dataset were compared. The MedAE of the Eom formula (0.22 D) was significantly smaller than that of the other four formulas, except for the Barrett Universal II and Ladas Super formulas (0.24 D and 0.23 D, respectively). The IOL FPI of the Eom formula was 0.553, which ranked first, followed by the Ladas Super (0.474), Barrett Universal II (0.470), Holladay 1 (0.444), Hoffer Q (0.396), Haigis (0.392), and SRK/T (0.361) formulas. In conclusion, the Eom IOL power calculator developed in this study demonstrated similar or slightly better accuracy than the Barrett Universal II and Ladas Super formulas and was superior to the four traditional IOL power calculation formulas.
Files in This Item
There are no files associated with this item.
Appears in
Collections
5. Others > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Eom, Youngsub photo

Eom, Youngsub
Ansan Hospital (Department of Ophthalmology, Ansan Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE