Detailed Information

Cited 16 time in webofscience Cited 18 time in scopus
Metadata Downloads

Percutaneous closure of perimembranous ventricular septal defect using patent ductus arteriosus occludersopen access

Authors
Hieu Lan NguyenQuang Tan PhanDung Duc DoanLinh Huynh DinhHieu Ba TranSharmin, SaimaThottian, Julian JohnyWon, HoyounLee, Wang SooShin, Seung YongTruong Quang NguyenKim, Sang Wook
Issue Date
Nov-2018
Publisher
Public Library of Science
Citation
PLoS ONE, v.13, no.11
Indexed
SCIE
SCOPUS
Journal Title
PLoS ONE
Volume
13
Number
11
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2021.sw.kumedicine/66024
DOI
10.1371/journal.pone.0206535
ISSN
1932-6203
Abstract
Objectives To assess the safety and efficacy of percutaneous closure of perimembranous ventricular septal defect (PmVSD) using patent ductus arteriosus (PDA) occluders. Background Widespread use of conventional PmVSD closure devices has been limited by unacceptable high rate of complete heart block (CHB). The elegant design of PDA occluders is supposed to ease implantation, increase closure rate and minimize damage to adjacent structures. Thus, PDA occluders may reduce complications, especially the CHB, and offer a good alternative for PmVSD closure. Method From September 2008 to October 2015, patients who underwent attempted percutaneous VSD closure using PDA occluders were included in the study. Patient demographics, echocardiography measurements, procedure details and follow-up data until October 2017 were collected. Results In total, 321 patients with a mean age of 15.5 +/- 12.6 years and mean a weight of 33.3 +/- 20.5 kg were included in this study. The mean defect size was 4.8 +/- 2.1 mm. Implantation was successful in 307(95.6%) patients. The median follow-up time was 63 months (24 to 108 months). The closure rates were 89.5%, 91.5%, and 99.3% after the procedure 24 hours, 6 months and 2 years, respectively. Major complications occurred in 5 (1.7%) patients during the procedure and follow-up, including persistent CHB in 2 (0.7%) patients and device embolization in 3 (1.0%) patients. No death, disability, or other major complication was detected. Conclusion Percutaneous closure of PmVSD using PDA occluders is feasible, safe and efficacious in selected patients.
Files in This Item
There are no files associated with this item.
Appears in
Collections
5. Others > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Seung Yong photo

Shin, Seung Yong
Ansan Hospital (Department of Cardiology, Ansan Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE